六合彩直播开奖

Designing Mode MUX/DEMUX Structures for Spatial Division Multiplexing Systems

Tools Used: BeamPROP, MOST

Spatial Division Multiplexing (SDM) for optical fiber transmission is useful for overcoming the capacity limit of wavelength division multiplexing. SDM increases the spectral efficiency per fiber by multiplexing the signals in orthogonal LP modes in few mode fibers (FMF) and multi-core fibers. In SDM systems, the mode multiplexer/demultiplexer (MUX/DEMUX) is a key component because it equalizes the mode-dependent loss, compensates for differential mode delays, and is used to construct transceivers. Different types of mode MUX/DEMUX have been proposed in recent years. RSoft BeamPROP is a great tool to model and design mode MUX/DEMUX.

This note will introduce the simulations for two proposed mode MUX/DEMUX structures for FMF. The first structure is a compact mode multiplexer using a 3D silicon-rich silica waveguide on a silicon chip, based on a paper by Hiraki et al.1 It can demultiplex three modes with an approximate 0.6mm^2 chip area. The second structure is a PLC-based asymmetric parallel waveguide to realize the mode conversion function by matching the effective indices of the LP01 and LP11 modes, based on a paper by Hanzawa et al.2 

Download Files

The (account required, please log in first).

On-Chip Integrated Silica MUX/DEMUX

Figure 1 shows a schematic of an on-chip-integrated mode multiplexer. The input from the FMF excites a set of symmetric supermodes. Symmetric modes evolve into distorted supermodes through an adiabatic tapered waveguide. Distorted supermodes are coupled into isolated ports, and then coupled into individual SMFs.

We have set up this structure in the RSoft CAD, as shown in Figure 2. Pathway monitors are used to measure the insertion loss. Spatial monitors are used to record the field at different locations. Figure 3 shows the propagation behaviors with three LP modes incident in the waveguide and their insertion loss along the propagation direction. Figure 4 shows field patterns at output ports and their insertion loss and crosstalk. Note that the structure setup is not completely identical to the one presented in the paper by Hiraki et al.1

Figure 1. Schematic of on-chip-integrated mode multiplexer | 六合彩直播开奖

Figure 1. Schematic of on-chip-integrated mode multiplexer

Figure 2. Layout in RSoft CAD and index profile at the beginning and the end | 六合彩直播开奖

Figure 2. Layout in RSoft CAD and index profile at the beginning and the end

Figure 3. The propagation field and the insertion loss along the structure | 六合彩直播开奖

Figure 3. The propagation field and the insertion loss along the structure

Figure 4. The field pattern and power output at each output ports corresponding to different input mode | 六合彩直播开奖

Figure 4. The field pattern and power output at each output ports corresponding to different input mode

Asymmetric Mode Coupler (AMC)

As shown in Figure 5, a PLC-based asymmetric mode MUX/DEMUX can be realized by matching the effective indices of the LP01 and LP11 modes of two waveguides with different widths. The LP01 mode from port 2 is converted to the LP11 mode in waveguide 1 and output at port 3, and the LP01 mode from port 1 is output directly at port 3. Thus, the LP01 and LP11 modes are multiplexed at port 3. The AMC can also be used as a mode DEMUX because the coupler has a symmetric property.

Figure 5. Schematic of proposed asymmetric PLC mode coupler | 六合彩直播开奖

Figure 5. Schematic of proposed asymmetric PLC mode coupler

Figure 6 shows the Neff for the fundamental mode and the first-order mode versus the waveguide width generated with an RSoft MOST scan. The Neff for the first-order mode matches with the fundamental- mode at different waveguide widths. If the coupler is configured at these two widths, then the fundamental mode of the narrower waveguide will be coupled into the first-order mode of the wider waveguide by the phase-matching condition.

Figure 6. Neff versus width of waveguide for fundamental and first-order modes | 六合彩直播开奖

Figure 6. Neff versus width of waveguide for fundamental and first-order modes

Figure 7 (a) The AMC structure setup in RSoft CAD | 六合彩直播开奖
Figure 7 (b) Coupling power versus coupling length | 六合彩直播开奖

Figure 7 (a) The AMC structure setup in RSoft CAD; (b) Coupling power versus coupling length

Figure 7 shows the AMC structure setup in RSoft CAD and the optimal coupling length from one mode to another generated with a BeamPROP simulation. With this optimal coupling length, Figure 8 shows how beam propagates with different incident conditions: LP01 mode of the narrower waveguide incident on Port 2; the LP02 mode of the wider waveguide incident on Port 1; and the equal power of two modes incident on Ports 1 and 2, respectively.

Figure 8. BPM simulations with different input conditions | 六合彩直播开奖

Figure 8. BPM simulations with different input conditions

The bandwidth, polarization dependence, and crosstalk (the power in the unwanted mode) can be obtained by scanning versus wavelength, as shown in Figure 9. This device can reach to 490 nm wide bandwidth with 0.005 dB polarization dependence and -28 dB crosstalk.

Figure 9. Device performance simulation results for bandwidth, polarization dependence, and crosstalk | 六合彩直播开奖

Figure 9. Device performance simulation results for bandwidth, polarization dependence, and crosstalk

Video Presentation

(account required).

References:

1.      Hiraki, T., Tsuchizawa, T., Nishi, H., Yamamoto, T., & Yamada, K. “Monolithically integrated mode multiplexer/de-multiplexer on three-dimensional SiOx-waveguide platform”, Optical Fiber Communication Conference (pp. W1A-2). Optical Society of America. (2015, March).

2.      Hanzawa, N., Saitoh, K., Sakamoto, T., Matsui, T., Tsujikawa, K., Koshiba, M., & Yamamoto, F. “Two-mode PLC-based mode multi/demultiplexer for mode and wavelength division multiplexed transmission” ,Optics Express21(22), 25752-25760 (2013).